Comparative metallurgical and eco-toxicological tests on Ele-auex product series vs Cyanide and Aqua regia on toxicity, work efficiency and operational costs reveal that Ele-auex has several advantages over cyanide and aqua regia in gold extraction processes. These advantages can be summarized as following:
In the electrolysis method, silver/gold plated parts can be instantly electrolyzed (gold/silver striped and precipitated on cathode plate directly) in the Ele-auex E series agent solution.
Au | Pt | Pd | Ag | In | Ir | |||
Zinc Cementation | 2.2 | 10.04 | 93.75 | 0.00 | 0.34 | 0.98 | 0.00 | 0.00 |
Chemical Precipitation | 2.2 | 10.03 | 94.75 | 0.00 | 0.00 | 1.34 | 0.03 | 0.00 |
Zinc Cementation | 1.0 | 1.39 | 87.59 | 1.21 | 1.19 | 2.40 | 0.04 | 0.15 |
Zinc Cementation | 1.4 | 6.34 | 94.67 | 0.00 | 0.00 | 1.22 | 0.00 | 0.00 |
The O series has better leaching performance than cyanide in gold ore lixiviation. For most common gold ores, Ele-auex (O) can reach a 90% leaching rate in 48 hours (CIL/CIP) while Ele-auex reagent consumption rate is lower than cyanide.
The charts below show original industrial CIP test results on sulphide (pyrite, arsenopyrite) gold ores at a gold mine in Myanmar with the Ele-auex O product series. Test results indicate that the Ele-auex O product series has better leaching performance in gold ore leaching kinetics (short leaching time), less reagent consumption rate (click the images to view their large size charts).